headlines
Model2596
support

Model 1834 Dynamic Focus CRT High Voltage Power Supply

  • Five output: anode, focus, G1, G2 and Dynamic Focus
  • Low line and load regulation of high voltage outputs
  • All outputs short circuit and arc protected - arc and short recovery tested
  • Remotely programmed shutdown for each output
  • Each output is current limited
  • Low focus ripple less than 2 V peak-to-peak due to anode transients
  • Very good cross regulation
  • Very low cross talk ripple

support

Model 1834 Dynamic Focus CRT High Voltage Power Supply has five outputs, all current limited, short circuit and arc protected and programmed to shutdown remotely. It features low focus ripple and excellent cross regulation.


support
General
Input voltage ± 35 VDC ± 10%
Input current 0.8 A maximum
Anode
Output voltage 12 kV ± 50 V
Output current 25 uA
Line regulation 2.4 V maximum for ± 10% of input voltage change
Load regulation 2.4 V maximum for no-load to full load swing
Output ripple 1.2 V peak-to-peak maximum at full load
Voltage metering 12 V full scale
Time stability 0.01% in hour
Temperature coefficient  200 ppm/ °C
High voltage connector LGH type (AMP 861253-1 or equivalent)
Focus
Output voltage 3 - 5 kV ± 10%
Output current 400 uA
Line regulation 6.0 V maximum for ± 10% of input voltage
Load regulation 12 V maximum for no-load to full load swing
Output ripple 6 V peak-to-peak maximum at full load
Voltage metering 5 V full scale
Time Stability 0.01% in hour
Temperature coefficient 200 ppm/ °C
High voltage connector LGH type (AMP 861252-1 or equivalent)
Dynamic Focus
Input voltage 0 - 10 V
Output voltage 0 - 300 V
Modulation frequency 3 kHz
Propagation time delay <5 us
Input resistance 1 MOhms
G1
Output voltage -70 V ± 3.5 V
Output current 5 mA
Line regulation 0.070 V maximum for ± 10% of input voltage change;
Load regulation 0.210 V maximum for no-load to full load swing
Output ripple 0.025 V peak-to-peak maximum at full load
Time stability 0.01% in hour
Temperature coefficient 200 ppm/ °C
G2
Output voltage 375 - 825 V ± 10 V potentiometer adjustable
Output current 600 uA
Line regulation 10.0 V maximum for ± 10% of input voltage change
Load regulation 5 V maximum for no-load to full load swing
Output ripple 1 V peak-to-peak maximum at full load
Time stability 0.01% in hour
Temperature coefficient 200 ppm/ °C

support
sales
Model 1834 Call CPS for availability