headlines
Model2596headlines
Model2596
support

Model 2594 | Electron Beam, Ion Beam, X-Ray Tube Power Supply

  • Very low output ripple (<300 mV p-p at full load at 50 kV and 500 uA)
  • Temperature coefficient <50 ppm/°C
  • Stored energy is low (<0.25 J at 30 kV)
  • Separate connection for HV output cable shield and programming reference
  • Over voltage and over current limited
  • Short-circuit and arc protected(<10ppm/hr) and tempco (<10 ppm/°C)
  • Automatic output voltage recovery after arcs and short circuits
  • Floating high voltage return available

support

Model 2594 is a high-stability power supply designed for the difficult requirements of focused ion and electron beam systems. It features low ripple and low stored energy. The low stored energy at the output reduces system upsets when arcing occurs. The low output ripple is the result of using sine wave excitation to the high voltage multiplier plus the use of a novel ripple cancellation circuit. Hence, low output ripple is achieved without using a large value output capacitor. The 2594 uses separate power return lines for the high voltage load, the input power and the voltage programming reference. Separating these signals reduces unwanted interactions between the critical programming reference and the other circuits. It also allows to reduce the 60 Hz noise resulting from AC line power input.


support
Input power 24VDC
Input current Maximum 0.3 A rms at 120 V rms
Output voltage Adjustable up to 50 kV maximum
Output current 500 uA maximum
Line regulation 0.005% for ± 10% change of input voltage
Load regulation 0.005% for full swing from no-load to full load
Output voltage noise and ripple Maximum 300 MVp-p at 50 uA load
Time stability 0.005% in 1 our, 0.01% in 8 hours
Operating temperature 0 to 50°C
Temperature coefficient <50 ppm/°C
Output connector CPS connector HVC 150 (CATON LGG 41 optional)
Program voltage 5 V for full scale output (10 V optional)
Voltage metering 1 V per 10 kV output
Current metering 1 V per 100uA output
Time stability 0.005% in 1 our, 0.01% in 8 hours
Operating temperature 0 to 50°C
Temperature coefficient <50 ppm/°C
Output connector CPS connector HVC 150 (CATON LGG 41 optional)
Program voltage 5 V for full scale output (10 V optional)
Voltage metering 1 V per 10 kV output
Current metering 1 V per 100uA output
sales
Model 2594 AC Qty 1. $2,475   Qty2-9. $2,250
Model 2594 DC Qty 1. $1,320   Qty2-9. $1,188