| Model | Output | Ripple | Stability | Input | Features |
| 550 | 0-5 kV, 40 mA | 0.1% at full scale | 120/220 VAC | UL and CE, For Electrophoreses use | |
| 560 | 0-10 kV, 25 mA | 0.1% at full load | Voltage 0.01% per hour, Current 0.05% | 120/220 VAC | Arc & short circuit protected Over voltage protection |
| 1210 | 0-20 kV, 300 uA | 150 mVpp | 0.005% in 1 hour, 0.01% in 8 hours |
120 VAC | Low stored energy |
| 130N/1314 | 0-30 kV, 500 uA | 200 mVpp | 0.005% in 1 hour, 0.01% in 8 hours |
120/220 VAC | AC & DC inputs Local/Remote programming |
| 1316 | 0-30 kV, 1 mA (0-20 kV at 2 mA avail.) | 200 mVpp | 20 ppm/C | 120 VAC | SEMI S2-93 Very low output ripple |
| 1487 | 0-15kV, 200 uA anode 3.2 kV to 5.3 kV, 250 uA focus 500 V, 50 uA G2 grid |
Less than 7.5 V peak-to-peak at full load | 0.01% in 1 hour | 28 VDC | Triple output CRT supply All outputs adjustable Compact size - 6 x 4 x 4 |
| 1561 | 0-12 kV, 500 uA | 0.1% at full load | 0.01% in 1 hour | 24 VDC | High stability Output current limited Compact size - 6 x 2 x 4 |
| 1617 | 0-20 kV, 200 uA anode 3-5 kV focus 300 V G2 grid |
<2 V under full load <1.5 V under full load <150 mV under full load |
28 VDC | Three output voltages: 20kV, 5 kV, 300 V Low output ripple Tight line and load regulation |
|
| 1641 | 0-10 kV, 200 uA anode 1 kV, 1 mA G2 grid |
2.0 volts in 8 hours | 18 VDC | 10 kV anode output G2 output Static and dynamic focus output |
|
| 1733 | 16 kV anode -105 V G1 grid 400 V G2 grid |
< 10 Vpp < 0.1 Vpp < 0.5 Vpp |
24 VDC | Three outputs: 16 kV, 400 V, -105 V 22 V to 24 V input Built to Mil 45208 standards |
|
| 1834 | 12 kV anode 3-5 kV focus -70 V G1 375-825 V G2 0-10 V dynamic focus |
See data sheet | 35 VDC | Five output: anode, focus, G1, G2 and Dynamic Focus Low line and load regulation of high voltage outputs All outputs short circuit and arc protected - arc and short recovery tested Very low cross talk ripple |
|
| 1844 | 4-level anode, focus G1/G2 grid |
17 V max at 17 kV 105 mV p-p max/1.6 V p-p max |
24 VDC | Replacement for Venus Scientific beam penetration power supply Rapid switching between 8 kV to 17 kV |
|
| 1848 | 5-level anode | 6 Vp-p at 6 kV 14 Vp-p at 14 kV |
28 VDC | Rapid switching beam penetration for flight simulators & FAA displays Replacement for Venus Scientific 271 beam penetration power supply |
|
| 1930 | 25 kV anode 5-8 kV focus -150 V G1 grid 200-800 V G2 |
<15 Vp-p < 1Vp-p < 0.5 Vp-p < 0.5 Vp-p |
28 VDC | Four output voltages: 25kV, 8 kV, 800 V, -150 V Low output ripple Tight line and load regulation |
|
| 1953 | 18 kV anode 3-5 kV focus 200 V G1 350-750 V G2 0-300 V dynamic focus |
4 V p-p at full load 6 V p-p at full load 0.2 V p-p at full load 1.5V p-p at full load |
Maximum 9 V in 8 hours Maximum 2 V in 8 hours Maximum 1 V in 8 hours Maximum 2.5 V in 8 hours |
28 VDC | Five outputs: anode, focus, G1, G2 and Dynamic Focus Low line and load regulation of high voltage outputs All outputs short circuit and arc protected - arc and short recovery tested Very low cross talk ripple Low temperature coefficient |
| 1966A | Multiple outputs accel focus float filament |
See data sheet | See data sheet | 120/220 VAC | Electron beam lithography application |
| 1966D | Multiple outputs decel focus float filament |
See data sheet | See data sheet | 120/220 VAC | Electron beam lithography application |
| 2091A | 13 to 30 kV at no load 5 to 25 kV at 10 uA |
108 to 132 VAC at .1 Amp Max, .05 AMP typical | Electrostatic supply Compact size Reliable solid state design Maintenance free |
||
| 2091B | 0 to 15 kV | 108 to 132 VAC at .1 Amp Max, .05 AMP typical | Electrostatic supply Compact size Reliable solid state design Maintenance free |
||
| 2581 | 0-15 kV 2 mA 0-30 kV 1mA |
50 mVpp | 0.01% per 8 hours after 0.5 hour warm up | 24 VDC | Low stored energy Soft start circuit |
| 2591 | 0-30 kV, 500 uA | 200 mVpp | 25 ppm/C | 24 VDC | Low stored energy High stability for x-ray |
| 2591P | 0-35 kV, 500 uA | 200 mVpp at 30uA | 10 ppm/C | 24 VDC | UL & CE listed at +30 kV, 100uA Low stored energy |
| BP2592 | +/- 30 kV | 300 uA | 100ppm/C | 115 VAC (230 VAC optional) | Reversible polarity 3 HV connectors Electrostatic supply |
| 2592 | 0-50 kV, 500 uA (30 & 50 kV option) |
200 mVpp at 40uA | 20 ppm/C | 24 VDC | UL & CE listed at - 40 kV, 100uA Very low ripple |
| 2594-10 | 0-10 kV, 5 mA | 100 mVpp | 20 ppm/C | 24 VDC | Very low ripple Low stored energy |
| 2593 | 0-15 kV, 1.5 mA | 200 mVpp | 50 ppm/C | 24 VDC | Low stored energy |
| 2594AC | 0-50 kV, 500 uA | 300 mVpp | 25 ppm/C | 120/220 VAC | Low stored energy |
| 2594DC | 0-50 kV, 500 uA | 300 mVpp | 25 ppm/C | 24 VDC | Low stored energy |
| 2596 | 0-30 kV, 200 uA (up to 1 mA option available) | <200 mVpp | 10 ppm/hr | 120 VAC 220 VAC Option |
Available with analog or digital meters. 1 mA max with external cooling |
| 2600-30 | 0-30 kV, 500 uA | See data sheet | <10ppm per 1 hour | 24 VDC | Wide output voltage range Very low ripple Excellent Stability Digital control from computer via optic fiber |
| 2600-60 | 0-60 kV, 500 uA | See data sheet | <10ppm per 1 hour | 24 VDC | Wide output voltage range Very low ripple Excellent Stability Digital control from computer via optic fiber |
| 5003AC | 0-2 kV, 5/10/20 mA | 5 mVpp | 0.01% in 1 hour, 0.02% in 8 hours | 120/220 VAC | Positive or negative outputs Internal or external programming AC line input |
| 5003DC | 0-2 kV, 5/10/20 mA | 5 mVpp | 0.01% in 1 hour, 0.02% in 8 hours | 28 VDC | Positive or negative outputs Internal or external programming DC line input |
| 6001 | -30 k, 500 uA beam 0-5 A 5 V filament |
300 mVp-p maximum | 0.01% per 8 hours |
120 VAC | Filament floats on beam |
| 6004 | -30 kV, 500 uA beam 0-5 A 5 V filament |
200 mVpp | 120 VAC | Filament floats on beam | |
| XPS50P50 | Beam up to 50 kV, 1 mA Filament 4 A, 5 V standard 5 A, 5 V optional |
<50 V p-p maximum | 24 VDC | X-ray power sources. Constant e-beam current. Remote program & metering. Safety interlock. Robust arc proof design |
| Model | Output | Ripple | Input | Isolation |
| 203 | 24 VDC, 4.5 A | 120 mV pp typical | 88-264 VAC | 3000 V isolation 47-440 Hz |
| 204 | 24 VDC, 5 A | 120 mV -p typical | 88-264 VAC | 3000 V isolation 47-440 Hz |
| 209 | 12-24V VDC nominal | 120 mV pp typical | 88-264 VAC | 3000 V isolation 47-440 Hz |
| Model | Description |
| HVP-250 Precision Divider Probe | Up to 50 kV precision divider probe calibrated for either 10 MOhm with 1,000:1 ratio or 10 GOhm with 1000:1 ratio or nearly infinite impedance with 10,000:1 ratio |
| HVP-500 Precision Divider Probe | Up to 100 kV precision divider probe calibrated for either 10 MOhm with 1,000:1 ratio or 10 GOhm with 10,000:1 ratio |
| Probecase | Protective storage case |
| HVC130 Cable | 30 kV cable using RG-8 coax and special CPS connector |
| HVC 150 Cable | 50 kV cable using RG-8 coax and special CPS connector |