headlines
Model2596
support

Model BXPS50P50 X-Ray Tube Power Supply

  • Anode voltage and emission current programming 0 to 10 V full scale
  • High stability emission current control loop. Emission current ramps to set point 2 seconds after power-up
  • Integrated filament supply
  • Safety HV interlock
  • Voltage and emission current metering 0 to 10 V full scale
  • Power ON, interlock closed and fault indicators
  • Over voltage, arc and short circuit protection
  • Low stored energy (<650 mJ)
  • Output power disabled by TTL input signal
  • Output power disabled if heat sink temp. >70°C

support

Notes: The filament supply is designed to maintain constant emission (beam) current. Filament power disabled until anode voltage established. The minimum and maximum filament current levels can be preset. The 24 VDC output signal is available and can be enabled when high voltage is on.


Manuals | Model XPS50P50 Manual

support

Input

Voltage 24 V DC ± 1 V
Current 4.4 A maximum

Output

Voltage + 50 kV
Current Up to 1 mA

Voltage Control

Local Internal multi-turn potentiometer to set the voltage from 0 to 50 kV
Remote 0 to +10 V DC for full scale of output voltage

Emission Control

Local Internal multi-turn potentiometer to set the beam current from 0 to 1 mA
Remote 0 to +10 V DC for full scale of output voltage

Filament Supply

Current 4 A standard, 5 V optional
Voltage 5 V maximum
Ripple <1%

Voltage regulation

Load ± 0.01% for full load swing
Line 0.01% for ± 10% for specified input voltage range

Current regulation

Load 0.01% for full load swing
Line 0.01% for specified input voltage range
Ripple <0.1% peak-to-peak of output voltage
Temperature range Operating: 0 to 50°C
Temperature coefficient 0.01% per °C
Stability 0.05% per 8 hours after 0.5 warm up
Approximate size 160 x 100 x 260 mm
Connectors I/O DB 9 or equivalent Molex or Phoenix connector assemblies for power and filament
HV output connector Coaxial cable type RG-8A/U
sales
Model XPS50P50 Qty 1. $1,373 Qty2-9. $1,248